Abstracts – Browse Results

Search or browse again.

Click on the titles below to expand the information about each abstract.
Viewing 14 results ...

Abudayyeh, O, Federicks, T, Palmquist, M and Torres, H N (2003) Analysis of Occupational Injuries and Fatalities in Electrical Contracting Industry. Journal of Construction Engineering and Management, 129(02), 152–8.

Ammar, A, Hanna, A S, Nordheim, E V and Russell, J S (2003) Indicator Variables Model of Firm’s Size-Profitability Relationship of Electrical Contractors Using Financial and Economic Data. Journal of Construction Engineering and Management, 129(02), 192–7.

Brown, D C (2003) Novel Method of Excavation. Journal of Construction Engineering and Management, 129(02), 222–5.

Brunso, T P and Siddiqi, K M (2003) Using Benchmarks and Metrics to Evaluate Project Delivery of Environmental Restoration Programs. Journal of Construction Engineering and Management, 129(02), 119–30.

Chua, D K H, Wang, Y and Tan, W T (2003) Impacts of Obstacles in East Asian Cross-Border Construction. Journal of Construction Engineering and Management, 129(02), 131–41.

Cox, R F, Issa, R R A and Ahrens, D (2003) Management’s Perception of Key Performance Indicators for Construction. Journal of Construction Engineering and Management, 129(02), 142–51.

Elliott, M E and Heymsfield, E (2003) Inspection of Luling Bridge Cable Stays: Case Study. Journal of Construction Engineering and Management, 129(02), 226–30.

  • Type: Journal Article
  • Keywords: Bridges, cable-stayed; Case reports; Louisiana; Bridge inspection; inspection; cable testing; civil engineering; safety; corrosion; corrosion testing;
  • ISBN/ISSN: 0733-9364
  • URL: https://doi.org/10.1061/(ASCE)0733-9364(2003)129:2(226)
  • Abstract:
    Most cable-stayed bridges in the United States have been built in the last 30 years. As the number of existing cable-stayed bridges increase, one problem continues to arise—how to inspect the cable stays for corrosion and deterioration. An inherent difficulty in developing an inspection procedure for cable-stayed bridges is that each cable-stayed bridge is unique in its cable configuration. The Louisiana Department of Transportation and Development (LADOTD) has built two separate trolleys to aid their inspectors and maintenance crew with visual inspection and maintenance of the cable stays on the Luling Bridge over the Mississippi River in St. Charles Parish near New Orleans, Louisiana. With the use of the two trolleys, LADOTD bridge inspectors are able to inspect the cable stays at hands-on distances. The cable-stay inspection procedure adopted by the LADOTD is inexpensive and time efficient, and it minimally impacts bridge traffic. This manuscript reviews the inspection procedure adopted by the LADOTD to inspect the cable sheathing at the Luling Bridge.

Hinze, J and Gambatese, J (2003) Factors That Influence Safety Performance of Specialty Contractors. Journal of Construction Engineering and Management, 129(02), 159–64.

Maloney, W F (2003) Labor-Management Cooperation and Customer Satisfaction. Journal of Construction Engineering and Management, 129(02), 165–72.

Marzouk, M and Moselhi, O (2003) Object-oriented Simulation Model for Earthmoving Operations. Journal of Construction Engineering and Management, 129(02), 173–81.

Palaneeswaran, E and Kumaraswamy, M M (2003) Knowledge Mining of Information Sources for Research in Construction Management. Journal of Construction Engineering and Management, 129(02), 182–91.

Schaufelberger, J E and Wipadapisut, I (2003) Alternate Financing Strategies for Build-Operate-Transfer Projects. Journal of Construction Engineering and Management, 129(02), 205–13.

Shi, J J and Halpin, D W (2003) Enterprise Resource Planning for Construction Business Management. Journal of Construction Engineering and Management, 129(02), 214–21.

Trost, S M and Oberlender, G D (2003) Predicting Accuracy of Early Cost Estimates Using Factor Analysis and Multivariate Regression. Journal of Construction Engineering and Management, 129(02), 198–204.